Search results for "lcsh:Medical technology"

showing 10 items of 25 documents

Mitochondrial targeting as a novel therapy for stroke

2018

Stroke is a main cause of mortality and morbidity worldwide. Despite the increasing development of innovative treatments for stroke, most are unsuccessful in clinical trials. In recent years, an encouraging strategy for stroke therapy has been identified in stem cells transplantation. In particular, grafting cells and their secretion products are leading with functional recovery in stroke patients by promoting the growth and function of the neurovascular unit – a communication framework between neurons, their supply microvessels along with glial cells – underlying stroke pathology and recovery. Mitochondrial dysfunction has been recently recognized as a hallmark in ischemia/reperfusion neur…

0301 basic medicinelcsh:Diseases of the circulatory (Cardiovascular) systemAginglcsh:Medical technologyimpaired mitochondriavasculatureBioenergeticmedicine.medical_treatmentClinical Trials and Supportive ActivitiesIschemiaregenerative medicineReview ArticleBioenergeticsMitochondrionblood–brain barrierBioinformaticsstem cell therapycerebral ischemiaCell therapy03 medical and health sciences0302 clinical medicineClinical Researchmedicineneurovascular unitStrokeTransplantationbusiness.industryNeurosciencesGeneral MedicineStem-cell therapyblood-brain barrierStem Cell Researchmedicine.diseaseendothelial cellsBrain DisordersReview articleStrokeTransplantationtransfer of healthy mitochondria030104 developmental biologylcsh:R855-855.5lcsh:RC666-701endothelial cellStem cellbusiness030217 neurology & neurosurgeryBrain Circulation
researchProduct

Evaluation of the antibacterial power and biocompatibility of zinc oxide nanorods decorated graphene nanoplatelets: New perspectives for antibiodeter…

2017

Background Nanotechnologies are currently revolutionizing the world around us, improving the quality of our lives thanks to a multitude of applications in several areas including the environmental preservation, with the biodeterioration phenomenon representing one of the major concerns. Results In this study, an innovative nanomaterial consisting of graphene nanoplatelets decorated by zinc oxide nanorods (ZNGs) was tested for the ability to inhibit two different pathogens belonging to bacterial genera frequently associated with nosocomial infections as well as biodeterioration phenomenon: the Gram-positive Staphylococcus aureus and the Gram-negative Pseudomonas aeruginosa. A time- and dose-…

3003Staphylococcus aureuslcsh:Medical technologyBiocompatibilitylcsh:Biotechnologyharmful to the environmentBiomedical EngineeringPharmaceutical ScienceMedicine (miscellaneous)Overall; ZNGs represent a promising candidate for developing biocompatible materials that can be exploitable in antimicrobial applications without releasing toxic compounds; harmful to the environment; Bioengineering; Medicine (miscellaneous); Molecular Medicine; Biomedical Engineering; Applied Microbiology and Biotechnology; 3003Biocompatible MaterialsBioengineeringNanotechnology02 engineering and technology010402 general chemistry01 natural sciencesApplied Microbiology and BiotechnologyNanomaterialsExtracellular polymeric substancelcsh:TP248.13-248.65HumansZNGs represent a promising candidate for developing biocompatible materials that can be exploitable in antimicrobial applications without releasing toxic compoundNanotubesbiologyChemistryResearchBiofilm021001 nanoscience & nanotechnologybiology.organism_classificationAntimicrobialAnti-Bacterial Agents0104 chemical scienceslcsh:R855-855.5NanotoxicologyBiofilmsPseudomonas aeruginosaZNGs; biodeterioration; antimicrobial nanomaterialMolecular MedicineGraphiteNanorodOverallZinc Oxide0210 nano-technologyBacteria
researchProduct

Unusual MRI findings in an immunocompetent patient with EBV encephalitis: a case report.

2011

Abstract Blackground It is well-known that Epstein-Barr virus (EBV) can affect the central nervous system (CNS). Case presentation Herein the authors report unusual timely Magnetic Resonance Imaging (MRI) brain scan findings in an immunocompetent patient with EBV encephalitis. Diffusion weighted MRI sequence performed during the acute phase of the disease was normal, whereas the Fast Relaxation Fast Spin Echo T2 image showed diffuse signal intensity changes in white matter. The enhancement pattern suggested an inflammatory response restricted to the brain microcirculation. Acyclovir and corticosteroid therapy was administered. After three weeks, all signal intensities returned to normal and…

AdultMalePathologymedicine.medical_specialtySettore MED/07 - Microbiologia E Microbiologia ClinicaEpstein-Barr virus encephalitis MRI Diffusion-weighted imaginglcsh:Medical technologyMononucleosisSettore MED/17 - Malattie InfettiveencephalitisCentral nervous systemCase Reportmedicine.disease_causeWhite matterImmunocompromised HostNeuroimagingmedicineHumansEpstein-Barr virusRadiology Nuclear Medicine and imagingInfectious Mononucleosismedicine.diagnostic_testbusiness.industrySettore MED/37 - NeuroradiologiaMagnetic resonance imagingmedicine.diseaseEpstein–Barr virusMagnetic Resonance Imagingmedicine.anatomical_structurelcsh:R855-855.5Radiology Nuclear Medicine and imagingDiffusion-weighted imagingbusinessEncephalitisDiffusion MRIMRIBMC medical imaging
researchProduct

In vivo biodistribution and lifetime analysis of cy5.5-conjugated rituximab in mice bearing lymphoid tumor xenograft using time-domain near-infrared …

2008

Rituximab is a chimeric monoclonal antibody directed against human CD20 antigen, which is expressed on B-cell lymphocytes and on the majority of B-cell lymphoid malignancies. Herein we report the conjugate of rituximab with the near-infrared (NIR) fluorophore Cy5.5 (RI-Cy5.5) as a tool for in vitro, in vivo, and ex vivo NIR time-domain (TD) optical imaging. In vitro, RI-Cy5.5 retained biologic activity and led to elevated cell-associated fluorescence on tumor cells. In vivo, TD optical imaging analysis of RI-Cy5.5 injected into lymphoma-bearing mice revealed a slow tumor uptake and a specific long-lasting persistence of the probe within the tumor. Biodistribution studies after intraperiton…

BiodistributionPathologymedicine.medical_specialtylcsh:Medical technologyLymphomamedicine.medical_treatmentIntraperitoneal injectionTransplantation HeterologousBiomedical EngineeringCarbocyanineMice SCIDBiologyIntestinal absorptionAntibodies Monoclonal Murine-DerivedMiceIn vivomedicineAnimalsHumansRadiology Nuclear Medicine and imagingAnimals; Antibodies Monoclonal; Antibodies Monoclonal Murine-Derived; Binding Sites; Carbocyanines; Cell Division; Female; Humans; Immunohistochemistry; Intestinal Absorption; Lymph Nodes; Lymphoma; Mice; Mice SCID; Neoplasm Transplantation; Rituximab; Transplantation Heterologouslcsh:QH301-705.5Binding SitesAnimaltechnology industry and agricultureBinding SiteAntibodies MonoclonalLymph NodeCarbocyaninesCondensed Matter PhysicsImmunohistochemistryTransplantationlcsh:Biology (General)lcsh:R855-855.5Intestinal AbsorptionMonoclonalMolecular MedicineImmunohistochemistryFemaleLymph NodesRituximabEx vivoCell DivisionNeoplasm TransplantationBiotechnologyHuman
researchProduct

3-D image analysis of fluorescent drug binding

2004

Fluorescent ligands provide the means of studying receptors in whole tissues using confocal laser scanning microscopy and have advantages over antibody- or non-fluorescence-based method. Confocal microscopy provides large volumes of images to be measured. Histogram analysis of 3-D image volumes is proposed as a method of graphically displaying large amounts of volumetric image data to be quickly analyzed and compared. The fluorescent ligand BODIPY FL-prazosin (QAPB) was used in mouse aorta. Histogram analysis reports the amount of ligand-receptor binding under different conditions and the technique is sensitive enough to detect changes in receptor availability after antagonist incubation or…

Boron CompoundsMalelcsh:Medical technologyAdrenergic receptorBiomedical EngineeringMouse aortaIn Vitro TechniquesAntibodieslaw.inventionMiceImaging Three-DimensionalConfocal microscopylawReceptors Adrenergic alpha-1HistogramAnimalsRadiology Nuclear Medicine and imagingReceptorlcsh:QH301-705.5Adrenergic alpha-AntagonistsAortaFluorescent DyesMice KnockoutMicroscopy ConfocalDose-Response Relationship DrugPhenoxybenzamineChemistryPrazosinBiological tissueCondensed Matter PhysicsFluorescenceAutofluorescencelcsh:Biology (General)lcsh:R855-855.5BiophysicsMolecular MedicineFemaleBiotechnology
researchProduct

The Short-Access Mother–Baby-(SAMBA) Cholangioscopy System

2014

Conventional mother–baby cholangioscopy systems have significant limitations including poor image resolution, limited maneuverability and fragile cholangioscopes. We propose the novel short-access mother–baby-(SAMBA) cholangioscopy system that involves a very short and flexible cholangioscope that is introduced in a dedicated mother duodenoscope with an extra distal side port. Clinical feasibility of this device is demonstrated in three complex cases with cholangiopathies. The strengths of SAMBA cholangioscopy are improved imaging quality and excellent maneuverability of the baby that allows access of small intrahepatic ducts. Evaluation of suspected intrahepatic biliary disease is an excel…

Cholangiopathymedicine.medical_specialtylcsh:Medical technologyNeoplasiabusiness.industryGastroenterologyVideoSecondary sclerosing cholangitisCholangiocellular carcinomamedicine.diseaseBiliary diseasePort (medical)lcsh:R855-855.5Cholangiocellular carcinomaLaser lithoripsyImaging qualitymedicineSecondary sclerosing cholangitisCholangioscopyMother–baby cholangioscopyRadiology Nuclear Medicine and imagingRadiologybusinessVideo Journal and Encyclopedia of GI Endoscopy
researchProduct

Size-isolation of superparamagnetic iron oxide nanoparticles improves MRI, MPI and hyperthermia performance.

2020

Journal of nanobiotechnology 18, 22 (2020). doi:10.1186/s12951-020-0580-1

Hyperthermialcsh:Medical technologyMaterials sciencelcsh:BiotechnologyDispersityBiomedical EngineeringIron oxidePharmaceutical ScienceMedicine (miscellaneous)NanoparticleContrast MediaBioengineering02 engineering and technology010402 general chemistry01 natural sciencesApplied Microbiology and BiotechnologyTheranostic Nanomedicinechemistry.chemical_compoundStructure-Activity RelationshipIron oxide nanoparticlesMagnetic particle imagingDynamic light scatteringlcsh:TP248.13-248.65medicineHumansHyperthermiaParticle SizeMagnetite Nanoparticlesmedicine.diagnostic_testResearchSPIONMagnetic resonance imagingDextransHyperthermia Induced021001 nanoscience & nanotechnologymedicine.diseaseImage EnhancementMagnetic Resonance Imaging0104 chemical scienceslcsh:R855-855.5chemistryMolecular MedicineMPI0210 nano-technologyIron oxide nanoparticlesBiomedical engineeringMRIJournal of nanobiotechnology
researchProduct

Synaptosomes: new vesicles for neuronal mitochondrial transplantation

2021

Abstract Background Mitochondrial dysfunction is a critical factor in the onset and progression of neurodegenerative diseases. Recently, mitochondrial transplantation has been advised as an innovative and attractive strategy to transfer and replace damaged mitochondria. Here we propose, for the first time, to use rat brain extracted synaptosomes, a subcellular fraction of isolated synaptic terminal that contains mitochondria, as mitochondrial delivery systems. Results Synaptosome preparation was validated by the presence of Synaptophysin and PSD95. Synaptosomes were characterized in terms of dimension, zeta potential, polydispersity index and number of particles/ml. Nile Red or CTX-FITCH la…

MaleFIS1Mitochondrial DNAlcsh:Medical technologylcsh:BiotechnologyBiomedical EngineeringPharmaceutical ScienceMedicine (miscellaneous)BioengineeringMitochondrionDNA MitochondrialApplied Microbiology and BiotechnologyMembrane Potentials03 medical and health sciencesDrug Delivery Systems0302 clinical medicinelcsh:TP248.13-248.65medicineAnimalsHomeostasisProtein Interaction Domains and MotifsNeurodegenerationDelivery system030304 developmental biologyMitochondrial transplantationSynaptosome0303 health sciencesbiologyChemistryResearchCytochrome cNeurodegenerationSynaptosomes Mitochondria Neurodegeneration Delivery system Mitochondrial transplantationCytochromes cmedicine.diseaseRatsCell biologyMitochondriaTransplantationlcsh:R855-855.5Cytoplasmbiology.proteinMolecular Medicine030217 neurology & neurosurgerySubcellular FractionsSynaptosomes
researchProduct

Potential Use of a Diluted High-relaxivity Gadolinium-based Intra-articular Contrast Agent for Magnetic Resonance Arthrography: An In-vitro Study

2019

Abstract Background Magnetic resonance arthrography (MRA) requires intra-articular injection of gadolinium-based diluted paramagnetic contrast material. To our knowledge, gadobenate dimeglumine (Gd-BOPTA) has never been used for intra-articular applications. Our aim was to test in vitro different concentrations of Gd-BOPTA to be potentially used to perform MRA. Methods Gd-BOPTA was diluted in saline (NaCl 0.9%) to achieve different concentrations (4 mmol/l; 2 mmol/l; 1 mmol/l; 0.67 mmol/l; 0.5 mmol/l). Six sets of five sterile pipes were prepared with 5 ml of each solution, five sets added with 0.5 ml of fresh synovial fluid. Two separate pipes were prepared with 5 ml of gadopentetate dimeg…

Malelcsh:Medical technologyArbitrary unitmedicine.medical_treatmentmedia_common.quotation_subjectGadoliniumContrast Mediachemistry.chemical_elementIn Vitro TechniquesInjections Intra-ArticularMeglumineNuclear magnetic resonanceIntra articularMagnetic resonance arthrographySynovial FluidGadobenate dimeglumineGadopentetate dimeglumineOrganometallic CompoundsmedicineHumansSynovial fluidContrast (vision)In vitro studyRadiology Nuclear Medicine and imagingArthrographySalineGADOBENATE DIMEGLUMINEAgedmedia_commonmedicine.diagnostic_testChemistryReproducibility of ResultsIn vitro studyMagnetic resonance imagingMiddle AgedMagnetic Resonance Imaginglcsh:R855-855.5FemaleResearch ArticleSeminars in Musculoskeletal Radiology
researchProduct

Trans-Abdominal Ultrasound Guided ERC in a Pregnant Woman With Bile Duct Stones

2014

Background: The change in lithogenicity of bile, increased stasis of bile and decreased gall bladder emptying are the possible reasons for an increased risk of gall stones during pregnancy. However, biliary interventions during pregnancy are associated with risks to both the pregnancy and developing fetus. ERC under fluoroscopic control as gold standard is associated with higher risk of premature labor and teratogenity. Methods and patient: We performed transabdominal ultra-sound guided ERC in one patient in the second trimenon with gall stones. While the hilus area is observed by ultrasound, the papilla is carefully cannulated with a guidewire. A contrast agent is applied in the common bil…

Ultrasound guided ERCPmedicine.medical_specialtylcsh:Medical technologydigestive systemPregnancymedicineFluoroscopyRadiology Nuclear Medicine and imagingFetusPregnancyCommon bile ductmedicine.diagnostic_testBile ductbusiness.industryUltrasoundGastroenterologyVideomedicine.diseaseSurgeryMajor duodenal papillamedicine.anatomical_structurelcsh:R855-855.5ComplicationbusinessBile duct stonesComplicationVideo Journal and Encyclopedia of GI Endoscopy
researchProduct